MR03 convert radio signals to MODBUS data output and vice-versa. 1.5 kms range (Line of sight). These can be used as receiver-transmitter modules. Work in the non-licenses frequency band (433/ 868 MHz) with 5 channels. Can work in point-2-point or point-2-multi-point mode.

PD10 is a converter of USB/ RS485 interfaces. Maximum transmission rate up to 1 Mb/s (depending on RS-485 wire length). Transparent for communication protocols. Galvanic separation protects computer USB ports. Compatible with Windows 2000, XP, Server 2003, Vista, Server 2008 (x86 and x64)

PD12 is a converter of USB/ 232 interface. Maximum transmission rate up to 921.6 kb/s (depending on RS-485 wire length). Modbus RTU/ ASCII communication protocols. Works on very low power (30mA @ 5V DC.) Small size and easy to install. CE approved

PD22 is a data logger device which can archive emergency events. Archiving of process data and stores 390,000 Records. Archiving of emergency events (44400 events). Data exchange consisting in transmission of demands from the master system to the specific device

PD8 is a converter of RS485/ Ethernet interface. Enables access to devices with RS-485 interfaces for master devices and SCADA applications through the Ethernet network (independent of the communication protocol).Different working modes(TCP/IP, Real Port Network Service & UDP Serial Bridge)

SM1 is module for analog inputs. It can do Conversion of standard signals and temperature into RS485/Modbus in 2 channels. Linear individual characteristics. Fixing on a TS35 rail. Mathematical functions realized between channels and on channels. Overall dimensions 22.5x120x100 mm.

SM2 is module of standard signals and temperature into RS-485 / MODBUS in 4 channels. Linear individual characteristics. Fixing on a TS35 rail. Mathematical functions realized between channels and on channels. 2 programmable OC outputs. Full galvanic separation between inputs.

SM2 is module of standard signals and temperature into RS-485 / MODBUS in 4 channels. Linear individual characteristics. Fixing on a TS35 rail. Mathematical functions realized between channels and on channels. 2 programmable OC outputs. Full galvanic separation between inputs.

SM4 is module of logic outputs. Control of actuators from monitoring systems or PLC over RS485. 4 relay outputs or 8 OC outputs steered through RS-485/Modbus. Fixing on a TS35 rail. Full galvanic separation between outputs (for relay outputs). Configuration through free LPConfig software.

SM5 is a module of logic inputs. Transferring information of machine state to monitoring systems and PLC. 8 relay logic inputs read out through RS-485/Modbus. Fixing on a TS35 rail. Signaling of input states on LED diodes. Full galvanic isolation. Configuration through the free LPConfig software.

SM7 is a radio transmission module destined for data transmission in the non-licensed 433 MHz or 868 MHz band with 10 channels. Controlled output power. Two coding types, Manchester and NRZ. Possibility to group modules operating in the same radio channel (addressed radio link). CE approved.

PD51 is a converter for RS232/RS485 interface. It enables to increase number of devices increase in the network. Ensures the automatic control of the data flow direction. It is galvanically isolated. Available in two formats viz. DIN Rail mount (as repeater) and portable type (converter).