Rishcon-V/I measures and convert AC V or I of RMS input signal to proportional 1or2 analog output load dependent Vdc or independent Idc. Universal Aux with accuracy ±0.2% & TRMS measurement. Onsite input output configurable, 7Segment LCD Display, RS485 communication.

Rishcon-Hz where output signal is proportional to measured frequency with1 or 2 analog output load dependent Vdc or independent Idc. Universal Aux with accuracy ±0.2%. Onsite input, output configurable, 7 Segment LCD Display, RS485 (Modbus) communication.

Rishcon-P converts active, reactive & apparent power of 1Ø /3Ø balanced or unbalanced loads into proportional 1or2 analog output load dependent Vdc or independent Idc. Universal Aux with accuracy ±0.2%,TRMS type Onsite input/output configurable,7 Seg LCD display, RS485

Rishducer E13 convert a 3 sine waves AC voltage (upto 750V) or Current (upto 10A) of sine waveform into proportional 3 analog output load dependent Vdc or independent Idc based on arithmetical mean value measuring, calibration to RMS with sine waveform, AC or DC Aux supply

Rishducer E15 convert a sine wave AC voltage (upto 500V) or Current (upto 6A) of sine waveform into proportional 1 or 2 analog output load dependent Vdc or independent Idc based on arithmetical mean value measuring, calibration to RMS with Sine waveform, AC or DC Aux supply

Rishducer Ixx /Vxx  series Tranducer is used to convert sine-wave or distorted AC current or voltage into proportional 1 or 2 analog output load dependent Vdc or independent Idc. Self powered or Aux supply with Accuracy ±0.5% or ± 0.2%. TRMS or Avg type measurement

F11/F12 convert Frequency in the range 45…65Hz or 360…440Hz of AC voltage (upto 480V) into proportional 1or2 analog output load dependent Vdc or independent Idc. AC/DC Aux with Accuracy of F11 ±0.5% & F12 ±0.2%.Open & short-circuit protection

 

P11 converts active,reactive sine or distorted signals of I(10A) or V(660V) of 1Ø or 3Ø balanced/unbalanced loads into proportional 1or2 analog load dependent Vdc or independent Idc by TDM-PDM measuring principle1,2,3 wattmeter method. AC/DC aux supply

 

C11 measures the phase angle between range of I(10A) or V(660V) of 1Ø or 3Ø balanced network having a sine wave into proportional 1 or 2 analog output load dependent Vdc or independent Idc. Based on Zero crossing measuring principle, AC/DC Universal Aux

C12 measures the phase angle difference of 2 synchronized supplies of 10 to 660V, measuring range ±60 and ±175 °el having a sine or distorted wave into proportional 1or2 analog output load dependent Vdc or independent Idc based on Zero crossing measuring principle with AC/DC Aux

Mxx series simultaneously measure several variables of electric power system converting them into 2,3 or 4 analog output, 2 or 4 digital output for signaling limits, power metering, limit output AND/OR, Output Simulation, acquisition of meter data, mark setting with universal supply

M40/30 simultaneously measure several variables of electric power system and converts them into 3 or 4 analog output, Modbus (RS485) communication, output &power system simulation, acquisition of meter data, password protect, 4 integrated energy meters, mark setting, universal Aux

M01 is a programmable with RS485 bus interface, enable users to determine and supervise several parameter of electric power system with Modbus (RS485), power system Simulation, acquisition of meter data, password protect, 4 integrated energy meters, mark setting. Universal aux

M00 is programmable with LONWORKS interface, enable users to determine and supervises several parameter of electric power system programmed using LONTALK file transfer protocol. The measured variables transferred by means of standard network variable types (SNVT). Universal aux

Rish Trans measures important electrical parameters in 3 phase network and replaces the multiple analog panel meters. Measures Electrical parameter like AC current, Voltage, Hz, P, Q, S, PF,QF, LF. The Instruments has 4 Analog output, RS232, RS485, 7 segment display (optional). Universal aux

P12O is a transducer of Impulses, Revolutions and Frequency. Impulse counting upwards and downwards. Digital filter of input signals. Mathematical functions: multiplication, division. Storage of minimal and maximal values.  Analog output & RS-485 Modbus digital interface. 2 alarm relays.

P18-Temperature & Humidity Transducer & P18L-Temperature or Humidity transducer. Calculation of selected physical quantities (dew-point temperature, absolute humidity-only P18). 2 analog outputs 0/4…20 mA or 0…10 V - P18 option. Storage of maximum and minimum values (only P18).

Rishcon-CA/CV measures and convert AC I or V input signal to proportional analog output load dependent Idc or independent Vdc. Wide Auxiliary power supply Aux with accuracy ±0.2% & TRMS measurement.Narrow housing, 22.5 mm.

Rishcon-CA/CV measures and convert AC I or V input signal to proportional analog output load dependent Idc or independent Vdc. Wide Auxiliary power supply Aux with accuracy ±0.2%, Narrow housing, 22.5 mm.