RISH Clamp 1000A/300A AC/DC

RISH Clamp 1000A/300A AC/DC

Datasheet

Unique Design
Rish clamp 1000A AC/DC is a highly innovative design for features those increases safety and comfort of user.
 
* Rotating clamp jaws facilitate the measurement at physically awkward positions, vertical bus bars, conductors placed at positions difficult to access.
 
* Clamp jaws can be opened or closed with the trigger placed at bottom side away from the jaws. This allows the user to place his/her hand at safer distance from live conductor. This greatly reduces exposure of human beings to electrical shocks
 
* Location and design of trigger eliminates fatigues caused by single finger operation. It allows spreading the force required to open the jaws over more than one finger to ensure comfortable operation.
 
* Comfortable operation of push buttons and function selector switch, in adverse field conditions.
 
Large Jaw Opening
Jaw opening of 55mm for standard wire diameter of 50mm
 
Narrow Body
Narrow housing for firm grip and easy to carry.
 
High Accuracy for low current measurement
The clamp meter can measure accurately at not only the High currents but also Low current ranges.
 
User selectable Backlit: (Optional)
It is possible to conduct measurement using the clamp meter during night time in darkness with the help of Backlit. The back lit can be switched ON or OFF by pressing a single key.
 
Temperature measurement
Temperatures from -200 to 800 °C using Pt 100 and Pt 1000 sensors.
 
AUTO POWER OFF
In order to save the power of the Batteries, the clamp meter will automatically shut OFF if it detects no activity for 10 minutes.
 
Analog Scale
Analog scale that updates at the rate 20 times/sec to observe fluctuations in input.
 
CONTINOUS ON MODE
In this mode, AUTO POWER OFF is disabled.
 
DATA Hold Function
By pressing DATA HOLD button, reading on the display can be latched for Hands free operation.
 
MIN,MAX Function
By pressing MIN/MAX button, the clamp meter will start recording latest Minimum and Maximum readings
 
NULL ZERO Correction for Resistance
For Low ohm measurement, the lead resistance can be compensated by pressing the shift key (Yellow Key)
 
NULL ZERO Correction for Capacitance
Null zero connection for capacitance. For nF range, stray capacitance can be compensated by shift key (Yellow Key)
 
AUTO and MANUAL ranging modes
In AUTO ranging mode the instrument automatically selects the range with best resolution depending on the applied input. In MANUAL ranging mode range is user selectable using MAN key.
 
Diode Measurement
For testing diode and transistors, diode measurement function is available.
 
Protection from dust and water
IP20 for terminals as per IEC60529
 
Applicable International Safety standards
600 V CAT IV/1000V CAT III as per International Safety standard IEC 61010-1- 2010