Touch screen graphics LCD Rish Master 3440i/3440iDL has touch sensible color graphics LCD display with resolution of 320x240. Active Energy - Class 0.2S as per IEC 62053-22 RTC (Real Time Clock) (RM440iDL) Inbuilt real time clock for display of date and time, along with time stamping for data logging and Event recording. Relay Output (Optional) Potential free, very fast acting relay contact. Configurable as :
Optional Analog Outputs ( 2 Outputs) 2 Analog outputs can be programmed from a list of input parameters. Data logging (RM440iDL) Meter has inbuilt 8MB Flash for datalogging. Following options are available:
Sag, Swell and Over Current (RM440iDL) Sag, Swell and Over Current detection and storage for recent 30 such events with their date & time of detection, duration (min. 100 msec) and start and end phase indication of the corresponding event. Direct remote access(Optional) Remote configuration of the Instrument and access of measured parameter via Modbus or through Ethernet interface (Modbus TCP/IP). Energy measurement Active energy Import (kWh), Active energy export (kWh) Reactive energy Inductive(kVArh), Reactive energy capacitive(kVArh), & Apparent energy (kVAh). Any of the parameters can be freely assigned to 2 optional pulse outputs. Programmable Energy format & Energy rollover count Customer can assign the format for energy display on MODBUS (RS485) in terms of W, kW or MW. Additional to this, customer can also set a rollover count from 7 to 9 digits, after which the energy will roll back to zero. The above settings are applicable for all types of energy. Auto Energy Ranging Count on Display The Energy count rollover from Watt to KWatt then to MWatt as energy increases over the period. THD and Individual Harmonics measurement The instrument can measure per phase THD of voltage & current, and individual (upto 31st) harmonics of voltage and current. Onsite selection of Auto scroll / Fixed Screen User can set the display in auto scrolling mode or fixed screen mode locally via front panel keys by entering into Programming mode or remotely. Phasor Diagram Pictorial representation of all 3 Phases (Voltage & Current) in terms of vectors. Phase Sequence indication The instrument can detect wrong phase sequence or failure of one of the input voltages and displays “phase error” message. Waveform Pictorial representation of all 3 phases Current & voltage in terms of sinusoidal waveform. User selectable CT and PT secondary The secondary of the Current Transformer (CT) and Potential Transformer (PT) can be programmed via front panel by entering into Programming mode or remotely via MODBUS (Rs485)/ Ethernet. User Assignable Registers for MODBUS Customer can assign MODBUS register address as per his need for faster response time. Parameter Screen recall In case of power failure, the instrument memorizes the last displayed screen. Compliance to International Safety standards Compliance to International Safety standard IEC 61010-1- 2010. Enclosure Protection for dust and water Conforms to IP 54 (front face) as per IEC60529. EMC Compatibility Compliance to International standard IEC 61326. |