Global Energy Efficiency Solution Company
Rishabh Instruments Limited
Synchroscope (SQ)

Synchroscope (SQ)

SQ96 Synchroscope indicates the phase & frequency difference between two AC alternators which are to be paralleled with the help of rotating LEDs. The meter is housed in UL 94 V-0 approved polycarbonate case and can be mounted in Mosaic mounting (cascading).

Download & Share

Polycarbonate housing having UL 94 V-0

All Rishabh meters are housed in robust case with classical finish. The case is made of polycarbonate, which is flame retardant and non-drip and confirms to international regulations UL 94 V-0. Polycarbonate is a very tough and light weight engineering plastic material which has got the best mechanical properties very close to a metallic housing. It is 10% glass filled, glass fibers give it extra toughness.

 Application 

  • The electronic Synchroscope is designed to provide an illuminated indication of actual phase difference between the BUS voltage (reference voltage) & the GENERATOR voltage (incoming voltage).
  • It denotes the actual frequency difference corresponding to the inverse of time taken for one rotation of the illuminated vector spot. When two alternators are paralleled, it is necessary that Voltage magnitude, frequency and phase must be same.
  •  Synchroscope is hence used to indicate the Phase & Frequency difference between two AC alternators, which are to be paralleled.

Synchroscope working

The rotation of the vector spot is with reference to the Bus voltage. If the vector spot LED turns clockwise, it indicates the GEN frequency is greater than the BUS frequency. It means the speed of the generator must be reduced by the operator. 

If the spot LED turns anticlockwise, the GEN frequency is less than the BUS frequency. In this case, speed of the generator must be increased.

If ‘T’ is the time taken for one rotation, the frequency difference can be calculated as 1/T = Af

Example : Let the bus frequency be 50Hz. The vector spot takes 10 seconds for one clockwise rotation. 1/10 = 0.1Hz.

The frequency difference = 0.1Hz. Hence we can infer that GEN frequency is 50.1Hz.

If the Frequency & Phase of BUS signal matches with those of GEN signal, the two green LEDs at 12 o’clock position glow. If the frequency matches & phase does not, then one red LED corresponding to the phase difference will glow.

 Favourable condition for ‘Switching in’ the Generator

  • Ensure that the frequency difference between two inputs is within the requirements of user as follows: Measure time taken for one complete rotation of the vector spot in SECOND (T).

            The frequency difference will be Af = 1/T (Hz)

  •  Provided the frequency difference is within acceptable limits, wait till the SYNC mark LEDs (two green LEDs at 12 o’clock position) glow. At this instant, it is safe to connect the GEN to BUS.

Terminal screws and clamps

Self lifting terminal screws are connected to the terminal clamps. Self lifted clamps gets lifted with the terminal screw while unscrewing, this simplifies clamping of the connectors or wire and save the time.

Terminal protection with click-fitting back cover

All Rishabh meters are supplied with a self-clicking back cover which covers the terminals. This is very important feature especially for the voltmeter because these meters are usually connected on the front panel which can be opened and can be hazardous for the engineer while the maintenance of the panel is being done. The self-click avoids problems of loosing the screws and washers.

 Mounting arrangement

The meter has a unique swivel clamp which could be mounted in any of the two different positions at 90 deg to each other. This makes the meter suitable for grid-racking so that a number of meters can be mounted horizontally or vertically in one rectangular cut-out. This feature is also useful because making one rectangular cut-out is more economical than making several cut-outs. The design of the housing and swivel is such that it can accommodate any panel thickness from 1mm to 40mm.

Easy replacement of glass and bezel

Easy replacement of glass and bezel is possible in Rishabh meters at customer end without any tool. The glass with zero knob and bezel are click fitted in the meter.

Related products

People Also Look For

Crafted with precision and reliability, our products ensure top performance and durability. Experience excellence with every measurement.

View All
Elapsed Time Meter

Elapsed Time Meter (Hours Run Meter)

ETM72 & ETM96 Elapsed Time Meters (Hours Run Meters) are used to monitor ON/RUN time of plant/equipment which allows the user to check functions such as Production Efficiency, Cost and service period monitoring.

Elapsed Time Meter

DIN Rail Moving Iron Meter (DE, DS, DG, FM 35)

EQ35, PQ35, VQ35 & ZQ35 meters measure AC/DC Voltage or Current and frequency. These meters are installed on 35mm Din rail, the mounting width is 45mm and it is housed in UL 94 V-0 approved polycarbonate case and can be mounted in Mosaic mounting (cascading).

Elapsed Time Meter

Challenger series meters

Challenger 361, 362, 363 & 364 meters measure AC/DC Voltage or Current and frequency. The design features detachable lower fascia which allows the flexibility of either surface or window mounting. These meters have a rear zero adjuster screw for tamperproof installation.

Elapsed Time Meter

Saxon series meters

Saxon 012 & 013 meters measure AC/DC Voltage or Current and frequency. The design features detachable lower fascia which allows the flexibility of either surface or window mounting. These meters can withstand high levels of shock, vibration, dirt & humidity.

Elapsed Time Meter

Anush Series meters

AN 011 & 012 meters measure AC/DC Voltage or Current and frequency. The design features detachable lower fascia which allows the flexibility of either surface or window mounting. These meters have a rear zero adjuster screw for tamperproof installation.

Elapsed Time Meter

Rish Vista

The RISH VISTA range of analog panel meters offers accurate measurement and indication of most electrical and electronic parameters in industry as per industrial standard case size.

Elapsed Time Meter

Vibrating Reed frequency meter (FQ)

FQ72 & FQ96 frequency meters measure frequency in the range of 45 to 65Hz with the help of thin steel strips called reeds placed in a row on a steel plate. The meter is housed in UL 94 V-0 approved polycarbonate case and can be mounted in Mosaic mounting (cascading).

Elapsed Time Meter

Moving Iron selector switch meter (SWT)

EQ SWT 72 & EQ SWT 96 moving iron selector switch meters measure rms values of AC Voltage or AC Current of 1 phase as well as 3 phase 3 wire & 4 wire systems. It is housed in UL 94 V-0 approved polycarbonate case and can be mounted in Mosaic mounting (cascading).