Rish Ducer E13 - Current / Voltage Transducer (3 Channel)

Rish Ducer E13 - Current / Voltage Transducer (3 Channel)

Rish ducer E13 converts a 3 sine waves AC voltage (upto 750V) or Current (upto 10A) of sine waveform into proportional 3 analog output load dependent Vdc or independent Idc based on arithmetical mean value measuring and calibration to RMS with sine waveform, AC or DC Aux supply

  • Up to 3 measuring inputs: AC currents or AC voltages sine wave-form, arithmetical mean value measurement, calibration to rms with sine waveform.
  • Three measuring outputs: DC current signal (load-independent) or DC voltage signal
  • Low power consumption / Smaller CT's & VT’s can be used
  • Provision for either snapping the transducer onto top-hat rails or securing it with screws to a wall or panel
  • Manufactured in SMD technology/compact & reliable
  • Screw terminals suitable for multistrand or thick solid wires.
  • Electric isolation between input/output and power supply (3.7 kV) / personnel protection assured
  • Electric isolation between channels is 500V

The transducer RISH Ducer E13 is used to convert a 3 sine wave AC Voltage or AC Current (depending on types) into a (load independent DC current or load independent DC voltage) 3 output signal. That can serve several receiving instruments, such as indicators, recorders, alarm units, etc.

Related products

People Also Look For

Crafted with precision and reliability, our products ensure top performance and durability. Experience excellence with every measurement.

View All
Elapsed Time Meter

Rish CON I11

Rish CON-I11 measures and converts the AC I input signal to proportional analog output load-dependent IDC or independent VDC. Self-auxiliary power supply with an accuracy of ±0.5%. 

Elapsed Time Meter

Rish CON M+ : Multi Function Transducer

Rish COM-M+ transducer is used to measure and convert parameters of a single-phase or three-phase AC system with an unbalanced or balanced load into a proportional load-independent DC Current  /  Voltage output signal. It also provides digital output which can be configured for energy pulse / limit / timer

Elapsed Time Meter

Rish CT Ducer - Current Transformers With Transducer

Current Transformers with Transducer for the measurement of AC current. Rish CT Ducer is a very reliable, efficient, and robust current transformer for the measurement of AC current. It provides 4 to 20 mA or 0 to 20 mA DC output.

Elapsed Time Meter

Rish CON - CA/CV (Dual Output)

The transducer Rish CON-CA/CV is a dual-output transducer that converts a sinusoidal AC current or AC voltage into a load-independent DC current or a load-independent DC voltage proportional to the measured value.

Elapsed Time Meter

Rish Ducer E13 - Current / Voltage Transducer (3 Channel)

Rish ducer E13 converts a 3 sine waves AC voltage (upto 750V) or Current (upto 10A) of sine waveform into proportional 3 analog output load dependent Vdc or independent Idc based on arithmetical mean value measuring and calibration to RMS with sine waveform, AC or DC Aux supply

Elapsed Time Meter

Rish Ducer M01 - Programable Multifunction Transducer (RS485 - Modbus Communication)

M01 is programmable with an RS485 bus interface that enables users to determine and supervise several parameters of the electric power system with Modbus (RS485), power system simulation, acquisition of meter data, password protection, 4 integrated energy meters, and mark setting. Universal aux

Elapsed Time Meter

Rish Ducer - M40 / M30 : Programable Multifunction Transducer

Rish Ducer M40/30 simultaneously measures several variables of the electric power system and converts them into 3 or 4 analog outputs, Modbus (RS485) communication, output &power system simulation, acquisition of meter data, password protection, 4 integrated energy meters, mark setting, universal Aux

Elapsed Time Meter

Rish Ducer Mxx Series - Programable Multifunction Transducer

Mxx series simultaneously measures several variables of the electric power system converting them into 2,3 or 4 analog outputs, 2 or 4 digital outputs for signaling limits, power metering, limit output AND/OR, Output Simulation, acquisition of meter data, mark setting with universal supply