Global Energy Efficiency Solution Company
Rishabh Instruments Limited
Rish Ducer TV808 - Isolating Amplifier

Rish Ducer TV808 - Isolating Amplifier

The purpose of the isolating amplifier RISH Ducer TV 808  is to electrically insulate input and output signals, respectively to amplify and / or change the signal level or type (current or voltage) of the input signals. The device has two channels and provides two independent isolating amplifiers in an extremely small space. The user has a wide choice of input and output ranges and can set the desired one with the aid of soldered jumpers (coarse adjustment) and potentiometers (fine adjustment).

Download & shares

Features and Benefits

  • Electric Isolation between input, output and power supply, prevents falsified measurement due to spurious potentials.
  •  Flexibility provided by more than 250 different input and output combinations selected by simply positioning soldered jumpers, helps in reduced stocking.
  •  Processes unipolar / bipolar and live zero signals provision for raising burden and signal conversion Green LED signals indicates device in operating condition.
  •  High Electrical Insulation between input and output - 2.3 kV, and power supply versus all other circuits - 3.7 kV
  •  Provision for either snapping the isolating amplifier onto top – hat rails or securing it with screw to a wall or panel.
  • Accuracy±0.2%

The amplifier fulfils all the important requirements and regulations concerning electromagnetic compatibility EMC and safety (IEC 1010 resp. EN 61 010). It was developed and is manufactured and tested in strict accordance with the quality assurance standard ISO 9001. 

A version with one input and two outputs is available that enables two electrically insulated outputs to be obtained from a single input signal. 

  • 252 standard input and output combinations selected by soldered jumpers
  • User - specific input and / or output ranges
  • Isolating amplifier with one input two electrically insulated outputs.
  • Power supply 24 ... 60 V DC / AC or 85 ... 230 V DC / AC
  • DC isolating amplifier to electrically insulate i/p & o/p signals at2.3KV &power supply at3.7KV or amplify the signal levels in 252 i/p [0..1000V, ±20mA, ±20V] o/p [±20mA, ±10V] combinations selected by soldered jumpers, R Load Max600 OHM  
Related products

People Also Look For

Crafted with precision and reliability, our products ensure top performance and durability. Experience excellence with every measurement.

View All
Elapsed Time Meter

Rish PI-101

The purpose of the Rish PI-101 is to electrically isolate input, outputs and power supply. The device has one input and provides one independent output

Elapsed Time Meter

Rish PI-102

The purpose of the RISH PI-102 is to electrically isolate input, outputs and power supply. The isolator fulfils all requirements and regulation concerning electromagnetic compatibility EMC and safety (IEC61326-1 and IEC 61010-1:2010).

Elapsed Time Meter

Rish CON TPT (96 X 96)

Rish CON TPT is a Tap position transducer which coverts resistance to proportional analogue output signal. Outputs can be given as input to either RTU or indicator or recording instrument. The device has one input channel and two independent outputs. Programmable input tap resistance (2/3/4 wire measurement) upto 25kOHM is converted to proportional 1 or 2 analog o/p signal either I DC or V DC, Universal AC/DC aux With LED Display.

Elapsed Time Meter

Rish Ducer TV808 - Isolating Amplifier

The purpose of the isolating amplifier RISH Ducer TV 808  is to electrically insulate input and output signals, respectively to amplify and / or change the signal level or type (current or voltage) of the input signals. The device has two channels and provides two independent isolating amplifiers in an extremely small space. The user has a wide choice of input and output ranges and can set the desired one with the aid of soldered jumpers (coarse adjustment) and potentiometers (fine adjustment).

Elapsed Time Meter

Rish Ducer PT602 - Configurable Transmitter

The transmitter Rish Ducer PT 602 Converts the input variable-a signal from a resistance thermometer Pt 100 to a temperature linear output signal. The analogue output signal is either an impressed current or superimposed voltage which is processed by other devices for purposes of displaying, recording and / or regulating a constant. Versions are available with 2,3,4 wire connections, 1 and 2 channel, i/p  and o/p, Measuring ranges configurable with DIP switches.

Elapsed Time Meter

Rish ducer V604 - Programmable Universal Transmitter

The universal transmitter RISH Ducer V 604 converts the input variable – a DC current or voltage, or a signal from a thermocouple, resistance thermometer, remote sensor or potentiometer – to a proportional 2 analogue output signal. The analogue output signal is either an impressed current or superimposed voltage which is processed by other devices for purposes of displaying, recording and/or regulating a constant. A considerable number of measuring ranges including bipolar or spread ranges are available.

Elapsed Time Meter

Rish CON SI-102 (Dual output DC isolator )

Rish CON SI-102 Two electrically isolated analog outputs prevent interference voltage and current. Solves grounding problem in meshed signal networks.The device has one input and provides two independent outputs in an extremely small space.

Elapsed Time Meter

Rish CON TPT - Programmable Tap position transducer (DIN mounted)

Tap position transducer Rish CON TPT converts resistance to proportional analogue output signal. The purpose of the Tap position transducer is to convert tap position of transformers to equivalent analogue output. Outputs can be given as input to either RTU or indicator or recording instrument. The device has one input channel and two independent outputs. Programmable input tap resistance(2/3/4 wire measurement) upto 25kOHM is converted to proportional 1 or 2 analog o/p signal either Idc or Vdc, Universal AC/DC aux With LED Display.