Global Energy Efficiency Solution Company
Rishabh Instruments Limited
Rish ducer V604 - Programmable Universal Transmitter

Rish ducer V604 - Programmable Universal Transmitter

The universal transmitter RISH Ducer V 604 converts the input variable – a DC current or voltage, or a signal from a thermocouple, resistance thermometer, remote sensor or potentiometer – to a proportional 2 analogue output signal. The analogue output signal is either an impressed current or superimposed voltage which is processed by other devices for purposes of displaying, recording and/or regulating a constant. A considerable number of measuring ranges including bipolar or spread ranges are available.

Download & shares

Features

  • Input variable (temperature, variation of resistance, DC signal) and measuring range programmed using PC/ Simplifies project planning and engineering (the final measuring range can be determined during commissioning). Short delivery times and low stocking levels
  •  Analogue output signal also programmed on the PC (impressed current or superimposed voltage for all ranges between – 20 and + 20 mA DC resp. – 12 and + 15 V DC) / universally applicable. Short delivery times and low stocking levels
  • Electric insulation between measured variable, analogue output signal and power supply / Safe isolation acc. to EN 61 010
  • Wide power supply tolerance / Only two operating voltage ranges between 20 and a maximum of 264 V DC/AC
  • Provision for either snapping the transmitter onto top-hat rails or securing it with screws to a wall or panel
  • Housing only 17.5 mm wide (size S17 housing)/ Low space requirement
  • Other programmable parameters: specific measured variable data (e.g. two, three or four-wire connection for resistance thermometers, “internal” or “external” cold junction compensation of thermocouples etc,) transmission mode (special linearized characteristic or characteristic determined by a mathematical relationship, e.g. output signal = f (measured variable)), operating sense (output signal directly or inversely proportional to the measured variable) and open circuit sensor supervision (output signal assumes fixed preset value between – 10 and 110%, supplementary output contact signalling relay) / Highly flexible solutions for measurement problems
  • All programming operations by IBM XT, AT or compatible PC running the self-explanatory, menu-controlled programming software, if necessary, during operation / No ancillary hand-held terminals needed
  • Digital measured variable data available at the programming interface/ Simplifies commissioning, measured variable and signals can be viewed on PC in the field
  • Standard software includes functional test program / No external simulator or signal injection necessary
  • Self-monitoring function and continuously running test program /automatic signalling of defects and device failure
  • Accuracy ±0.2%

Input variable and measuring range are programmed with the aid of a PC and the corresponding software. Other parameters relating to specific input variable data, the analogue output signal, the transmission mode, the operating sense and the open-circuit sensor supervision can also be programmed.

The open-circuit sensor supervision is in operation when the Rish Ducer V 604 is used in conjunction with a thermocouple, resistance thermometer, remote sensor or potentiometer.

The transmitter fulfils all the important requirements and regulations concerning electromagnetic compatibility EMC and Safety (IEC 1010 resp. EN 61 010). It was developed and is manufactured and tested in strict accordance with the quality assurance standard ISO 9001.

Production QA is also certified according to guideline 94/9/EG.

Open circuit sensor supervision, trip point setting(-10to110%) Universal AC/DC Aux.  Automatic calibration for lead compensating

Related products

People Also Look For

Crafted with precision and reliability, our products ensure top performance and durability. Experience excellence with every measurement.

View All
Elapsed Time Meter

Rish PI-101

The purpose of the Rish PI-101 is to electrically isolate input, outputs and power supply. The device has one input and provides one independent output

Elapsed Time Meter

Rish PI-102

The purpose of the RISH PI-102 is to electrically isolate input, outputs and power supply. The isolator fulfils all requirements and regulation concerning electromagnetic compatibility EMC and safety (IEC61326-1 and IEC 61010-1:2010).

Elapsed Time Meter

Rish CON TPT (96 X 96)

Rish CON TPT is a Tap position transducer which coverts resistance to proportional analogue output signal. Outputs can be given as input to either RTU or indicator or recording instrument. The device has one input channel and two independent outputs. Programmable input tap resistance (2/3/4 wire measurement) upto 25kOHM is converted to proportional 1 or 2 analog o/p signal either I DC or V DC, Universal AC/DC aux With LED Display.

Elapsed Time Meter

Rish Ducer TV808 - Isolating Amplifier

The purpose of the isolating amplifier RISH Ducer TV 808  is to electrically insulate input and output signals, respectively to amplify and / or change the signal level or type (current or voltage) of the input signals. The device has two channels and provides two independent isolating amplifiers in an extremely small space. The user has a wide choice of input and output ranges and can set the desired one with the aid of soldered jumpers (coarse adjustment) and potentiometers (fine adjustment).

Elapsed Time Meter

Rish Ducer PT602 - Configurable Transmitter

The transmitter Rish Ducer PT 602 Converts the input variable-a signal from a resistance thermometer Pt 100 to a temperature linear output signal. The analogue output signal is either an impressed current or superimposed voltage which is processed by other devices for purposes of displaying, recording and / or regulating a constant. Versions are available with 2,3,4 wire connections, 1 and 2 channel, i/p  and o/p, Measuring ranges configurable with DIP switches.

Elapsed Time Meter

Rish ducer V604 - Programmable Universal Transmitter

The universal transmitter RISH Ducer V 604 converts the input variable – a DC current or voltage, or a signal from a thermocouple, resistance thermometer, remote sensor or potentiometer – to a proportional 2 analogue output signal. The analogue output signal is either an impressed current or superimposed voltage which is processed by other devices for purposes of displaying, recording and/or regulating a constant. A considerable number of measuring ranges including bipolar or spread ranges are available.

Elapsed Time Meter

Rish CON SI-102 (Dual output DC isolator )

Rish CON SI-102 Two electrically isolated analog outputs prevent interference voltage and current. Solves grounding problem in meshed signal networks.The device has one input and provides two independent outputs in an extremely small space.

Elapsed Time Meter

Rish CON TPT - Programmable Tap position transducer (DIN mounted)

Tap position transducer Rish CON TPT converts resistance to proportional analogue output signal. The purpose of the Tap position transducer is to convert tap position of transformers to equivalent analogue output. Outputs can be given as input to either RTU or indicator or recording instrument. The device has one input channel and two independent outputs. Programmable input tap resistance(2/3/4 wire measurement) upto 25kOHM is converted to proportional 1 or 2 analog o/p signal either Idc or Vdc, Universal AC/DC aux With LED Display.