Rish Delta Power NX

Rish Delta Power NX

Datasheet
  • True RMS Measurement
  • 3 Line, 4 Digit Ultra-bright LED display
  • Reliable and accurate measurement
  • Wide-range AC / DC auxiliary power supply  
  • Touch keys for user-friendly display access and configuration
  • On site programmable PT/CT ratios
  • Limit Output (Optional)
  • MODBUS (RS485) Output (Optional)
  • On-site System Programmable: 3 phase 4 wire, 3 phase 3 wire, 1 phase 2 wire, 1 phase 3 wire (split-phase) network
  • Display of minimum and maximum values
  • Current and power demand monitoring  
  • Password-protected setup mode
  • Low back depth-27mm
  • Compliance to International Safety standard
  • IEC 61010-1- 2018
  • Compliance to International standard IEC 61326

On site programmable PT/CT ratios
It is possible to program primary of external potential
Transformer (PT), primary of external Current Transformer (CT) on site via front panel keys by entering into Programming mode.
 
User selectable CT Secondary 5A/1A
The secondary of external Current Transformer (CT) can be programmed on site to either 5A or 1A using front panel keys.
 
User selectable PT Secondary
The secondary of external Potential Transformer (PT) can be programmed on site from 100VLL to 500VLL using front panel keys.
 
User selectable 3 phase 3Wire or 4Wire or 1 phase 2 Wire or 1 phase 3Wire Network
User can program on site the network connection as either 3 Phase 3 Wire or 4 Wire or 1 phase 2 Wire or 1 phase 3 Wire network using front panel keys.
 
Storage of parameters possible
The instrument stores minimum and maximum values for System Voltage, System Current, Run Hour, ON Hour & number of Interrupts. Every 60 sec stored values are updated.
 
Two Touch keys
Using the touch keys, it is possible to go desired parameter screen instantly.
 
Onsite selection of Auto scroll / Fixed Screen
User can set the display in auto scrolling mode or fixed screen mode using front panel keys.
 
Low back depth
The instrument has very low back depth (behind the panel) of less than 27 mm. using front panel keys.
 
True RMS measurement
The instrument measures distorted waveform up to 15th Harmonic.
 
RPM Measurement
The instrument display Rotation per minutes for generator applications. can be set on site depending upon Number of poles application requirement.

Optional MODBUS (RS485) Output
The optional MODBUS output enables the instrument to transmit all the measured parameters over standard MODBUS (RS485). 
 
Configuration of Instrument via MODBUS
The instrument setting can be configured locally via front panel  keys by entering into the programming mode or remotely via  MODBUS (RS485).
Note : The  MODBUS (RS485) communication parameters can only be set locally via front panel keys in programming mode.

Optional Limit switch (Relay)
The instrument will trip the relay if the programmed parameter exceeds the programmed Trip Limits.
 
3 line 4 digits LED display
Simultaneous display of 3 Parameters.
 
Enclosure Protection for dust and water
Conforms to IP 50 ( for front face) & IP 20 (for back) as per IEC 60529.
 
EMC Compatibility
Compliance to International standard IEC 61326.